imxrt_ral::lcdif::VDCTRL4

Module SYNC_SIGNALS_ON

source
Expand description

Set this field to 1 if the LCD controller requires that the VSYNC or VSYNC/HSYNC/DOTCLK control signals should be active at least one frame before the data transfers actually start and remain active at least one frame after the data transfers end